It is recommended to perform a factory reset on a fridge before assessing for fault, as altered fridge settings outside the scope of what is covered in the manual may lead to a variety of issues.
How to perform a factory reset for plastic-case portable fridges:
- On standby (plugged in but power off), press the set key until the display shows E1.
- Press + and – simultaneously until the display shows -188 (or 888 or 000)
- Press the power button to restart
See this video on how to do this: https://bmc.worldmanager.com/go/WNPWs1
If your fridge has a divider, make sure the divider is inserted, with the small plastic plug located at the bottom of the fridge, as this contains a magnet that controls how the zones work.
The fridge should then be left on for a minimum of 5 minutes to allow the compressor time to start up before troubleshooting can begin.
How to perform a factory reset for the Stainless Steel portable fridges (e.g. GH1646):
- Press the power button to turn off the unit.
- Press + Hold the 'Compressor Speed' button until 888 appears on the temp displays.
- Press the power button to finalise.
- All temps and settings will be set back to default.
Brass Monkey Fridge diagnostic error codes
Error | Fault | Common Fix |
F1 | Battery protection mode | There are 3 levels of battery protection. The default is H(igh) and offers the best protection, however, may cause issues when running from a battery or vehicle using a long lead. To adjust the protection mode, press Set for 3 seconds, screen flashes H. If error code F1, set to M(edium) or L(ow). |
F2 | Fan overload protection mode | Switch it off for 30 minutes to allow the system to cool down. Please ensure there is adequate ventilation around the fan vents. |
F3 | Compressor frequent start protection mode | Switch it off for 30 minutes to allow the compressor to cool down. Ensure the fridge is stored out of direct sunlight in a cool area. Make sure the vents are not covered by nearby obstructions and air can flow into and out of the vents. |
F4 | Compressor is overloaded mode | |
F5 | Compressor high temperature protection mode | |
F6 | Controller detection error | Switch off and then on again after a minute. If issue persists a connection may be loose due to vibration or a manufacturing issue. |
F7 | Temperature sensor error | faulty sensor terminal, refer instructions. |
F8 |
If you are still having issues & have performed a factory reset & are not seeing an error code, please contact your local Jaycar store for further support.
Comments
0 comments
Article is closed for comments.